SENHO air cooled inverter chiller
VFA Series

Air Cooled Inverter Chillers

General Information

  • Cooling Capacity Range: 7KW to 300KW
  • Max Working Ambient Temp: 45℃
  • Temp Control Range: 5℃ to 30℃
air cooled condenser type icon
Air Cooled Condenser
inverter drive icon
Inverter Drive
eco friendly icon for SENHO water chiller
Eco-friendly R407c Refrigerant
screw compressor icon for SENHO water chiller
Screw Type Compressor

Uncompromising Build Quality

True reliability starts from within. We integrate only world-class components into our systems. Hover over the blue markers to explore the robust architecture and intelligent design that guarantee stable cooling for your critical processes.

SRA100W1-air-cooled-screw-chiller.webp

Transparent water proof door, IP54 electrical enclosure provides reliable dust and splash protection for safe industrial equipment operation.

central chiller touch screen interfaceEquipped with a Siemens PLC and an intuitive touch screen, the interface offers real-time monitoring and precise control for effortless operation.

Epoxy resin coating and hydrophilic aluminum fins, this robust condenser ensures superior corrosion resistance, optimal heat dissipation, and an extended lifespan in harsh industrial environments

Selected for high efficiency, these axial fans feature aerodynamically optimized serrated blades to deliver powerful airflow and exceptional condenser heat exchange performance.

bizter-hanbell-screw-compressorEquipped with a world-class inverter-driven compressor that adjusts its speed in real-time based on actual thermal load. 

Delta Inverter for inverter chillers

Industrial-grade Delta or Mitsubishi VFDs, providing smooth and stable frequency control.

Standard Features

  • Inverter-Driven Compressors: Powered by world-class variable frequency scroll or screw compressors. Featuring stepless capacity modulation (25%-100%), they automatically adjust motor speed to match your exact thermal load, eliminating energy-wasting ON/OFF cycles and maximizing part-load efficiency (IPLV).
  • Premium VFD Technology: Equipped with top-tier Variable Frequency Drives from globally trusted brands like Delta or Mitsubishi. This ensures a smooth “soft start” with ultra-low starting current, significantly reducing mechanical wear and electrical stress on your facility’s power grid.
  • Variable Speed EC Fans & Condensation: Features a high-efficiency finned-tube condenser array paired with advanced EC (Electronically Commutated) axial fans. The fan speed dynamically syncs with the compressor load, providing exceptional heat dissipation while drastically reducing noise and fan power consumption.
  • Next-Generation PLC & PID Control: A built-in Siemens microprocessor continuously monitors dynamic loads. Combined with advanced PID algorithms, it guarantees ultra-precise water temperature regulation (up to ±0.1∘C to 0.5∘C variance) for highly sensitive industrial processes.
  • High-Performance Shell-and-Tube Evaporator: Designed with heavy-gauge materials to provide superior heat transfer rates, excellent resistance to fouling, and simplified maintenance for continuous, non-contaminating fluid cooling.
  • Comprehensive VFD & System Protection: Built-in safeguards include standard high/low pressure and flow switches, plus dedicated VFD protections such as over-voltage, under-voltage, phase loss, and inverter overheating protection.

Key Components

Delta Inverter for inverter chillers
Delta / Mitsubishi Inverter
Schneider electric parts for senho industrial chiller
Schneider Electric Parts
Inverter Compressor
World Class Inverter Compressor
Epoxy Coated Condenser for senho industrial chiller
Epoxy Coated Condenser
Shell and tube econdenser for water cooled chillers
High-Efficient Shell & Tube Evaporator
High-Efficiency Axial Fans for senho industrial chiller
High-Efficiency Axial Fans

Available Options

  • Plug-and-Play Hydronic Module: Streamline your site installation with our factory-integrated pumping station. Includes custom-engineered chilled water pumps and insulated buffer tanks, fully assembled and tested for immediate system readiness.
  • Corrosion Protection Coating: Advanced epoxy treatments (such as hydrophilic fins or specialized anti-corrosion coatings) for the condenser coils, highly recommended for outdoor installations near coastal areas or in chemically aggressive atmospheres.
  • Extreme Climate Adaptability: Custom engineering available for harsh environments. Choose from oversized tropical condensers for high-ambient heat (up to 60°C) or specialized winter operation kits for reliable starting in sub-zero climates (down to -40°C).
  • IoT & Remote Diagnostics Ready: Include an integrated Wi-Fi/4G connectivity module and standard RS-485 communication interfaces, enabling seamless BMS integration and real-time mobile monitoring for rapid remote diagnostic support.

Specification Table

Model(VFAXXX)030W1040W1050W1060W1075W1085W1100W1120W1140W1150W1160W1180W1210W1250W1
Cooling CapacityKW19~7626.25~10534.25~13737.5~15050~20058~23268.25~27380~32097~388101.25~405112~448122.5~490148.25~593173.75~695
Full Loade Power Input1KW30.240.249.55671.591.595.9116.5140.2143.2156.3163.7195.2229.7
Compressor Power KW27.536.445.750.365.882.186.5103.5124127142.6150178.7210.5
Condenser Air volumem³/h300004000050000600007500085000100000120000142000150000160000180000210000250000
Condenser PowerKW2.73.83.85.75.79.49.41316.216.213.713.716.519.2
Evaporator Chilled Water Flow2m³/h131824263440475567707784102119
Chilled Water Pipe Sizeinch3″3″3″3″3″4″4″4″5″5″5″5″6″8″
DimensionL(mm)19002200220027602760360036004000428055005500550065007600
W(mm)14801760176017601760180018002100210021002100210021002100
H(mm)19002050205020502050220022002200220022002200220022002200
Weightkg11501300160019002250240028503250400041004500480055006000

Note: The above parameters apply to models configured with single screw compressor. For other cooling capacities or compressor types, please contact the SENHO technical team.

1 Rated power of the unit is based on 3Ph 400V 50Hz power supply. 2 Water flow rate is a nominal design value based on a 5°C ΔT. Actual flow depends on pump performance and site piping layout.

Related Products